<?xml version="1.0" standalone="yes"?>
<?xml-stylesheet type="text/xsl" href="..\..\XSLTemplates\NVSStyleSheet.xsl"?>
<Parameter>
<ParameterFamily>EHI</ParameterFamily>
<Syntax>
head hpoffset
</Syntax>
<AppliesTo>
<UnnumberedList>
<ListItem><TextApplies>Gravure</TextApplies></ListItem>
<ListItem><TextApplies>Japanese_Newspaper_OEM_Engine</TextApplies></ListItem>
<ListItem><TextApplies>Lotem_Quantum</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_400</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_800</TextApplies></ListItem>
<ListItem><TextApplies>Magnus_VLF</TextApplies></ListItem>
<ListItem><TextApplies>Slave_MCE_Firmware</TextApplies></ListItem>
<ListItem><TextApplies>Thermoflex</TextApplies></ListItem>
<ListItem><TextApplies>Think_Motion_Controller</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_400/800</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_NEWS</TextApplies></ListItem>
<ListItem><TextApplies>Trendsetter_Series_4</TextApplies></ListItem>
</UnnumberedList>
</AppliesTo>
<Description>
<DescriptionText><text>
Used in conjunction with the "hpslope" parameter to convert the raw results of
"head power full" and "head power off" measurements into Watts out of the head.
This parameter value is only used with "head power full" when using "head
power off" the actual offset to use is measured.
</text></DescriptionText>
<DescriptionText><text>
The raw reading of the shutter sensor is affected by the "head hpwrgain"
parameter setting so changing this value will require commensurate changes to
"hpoffset".
</text></DescriptionText>
<DescriptionText><text>
This value can only be calibrated if an external power meter is available and
hence this parameter should not be changed from its factory setting.
</text></DescriptionText>
</Description>
<Availability>
<DescriptionText><text>
This parameter is available.
</text></DescriptionText>
</Availability>
<Default>
<UnnumberedList>
<li>Please issue the appropriate monitor command to determine this parameter's default value.</li>
</UnnumberedList>
</Default>
<Range>
<UnnumberedList>
<li>Please issue the appropriate monitor command to determine this parameter's minimum and maximum values.</li>
</UnnumberedList>
</Range>
<LastModified>
07-May-2002
</LastModified>
<Notes>
<DescriptionText><text>
Note that the "head power sum" command is the more reliable way to measure
power out of the head with firmware versions greater than 1.5.
</text></DescriptionText>
</Notes>
<Access>
Normal
</Access>
<SeeAlso>
<UnnumberedList>
<li><Link><LinkAddress>../prm/ehi_head_hpslope.xml</LinkAddress><LinkTitle>PRM: head hpslope</LinkTitle></Link></li>
<li><Link><LinkAddress>../prm/ehi_head_hpwrgain.xml</LinkAddress><LinkTitle>PRM: head hpwrgain</LinkTitle></Link></li>
<li><Link><LinkAddress>../commands/head_power.xml</LinkAddress><LinkTitle>Command: head power</LinkTitle></Link></li>
</UnnumberedList>
</SeeAlso>
<OtherLinks>
<li><Link><LinkAddress>..\..\ShowAllErrors.htm</LinkAddress><LinkTitle>Firmware 1 Error Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllCommands.htm</LinkAddress><LinkTitle>Firmware 1 Command Index</LinkTitle></Link></li>
<li><Link><LinkAddress>..\..\ShowAllParameters.htm</LinkAddress><LinkTitle>Firmware 1 Parameter Index</LinkTitle></Link></li>
</OtherLinks>
<Updated>
Updated: Thu Jul 17 07:23:57 2008 PST
</Updated>
<Links>
</Links>
</Parameter>